Amiblu GRP joints and couplings

Amiblu pipes are typically joined using GRP couplings. All Amiblu GRP pipe solutions have a proven jointing system that secures the systems work through its whole estimated service life. The system also offers solutions for transitions to other materials such as connection to valves or other accessories. Pipes and couplings can be alternatively supplied separately or pre-assembled at one of the female pipe ends.

Pressure couplings

Hobas filament wound coupling illustration

Used in pressure and non-pressure pipelines.

Diameter range (DN)200-2400 mm
Pressure (PN)< DN 1000: up to 16 bar

> DN 1000: max. 16 bar

Angular deflection*up to 3°
Flowtite pressure coupling illustration

Commonly used for penstocks, water supply, irrigation and pressure sewer applications.

Diameter range (DN)100-4000 mm
Pressure (PN)up to 32 bar
Angular deflection*up to 3°
Flowtite pressure coupling angled illustration

Flowtite coupling for increased angular deflections up to 3 degrees.

Diameter range (DN)300-2500 mm
Pressure (PN)up to 16 bar
Angular deflection*
Flowtite lock joint illustration

Biaxial joint used for applications where transfer of load between pipes is required.

Diameter range (DN)300-2000 mm
Pressure (PN)6-16 bar
Angular deflection*not applicable

Non-pressure couplings

Flowtite non-pressure coupling illustration

Commonly used for sewer and stormwater applications with Flowtite pipes.

Diameter range (DN)300-3000 mm
Pressure (PN)1 bar
Angular deflection*up to 3°
Amiblu non-pressure coupling illustration

Alternative coupling for sewer and stormwater applications with Hobas pipes.

Diameter range (DN)200-3000 mm
Pressure (PN)1 bar
Angular deflection*up to 3°

* The degree of angular deflection is dependent on the pipe diameter. Contact your local supplier for more information.

Flush joints

Amiblu GRP sleeve illustration

Commonly used for jacking and relining. Fits centrifugally cast and filament wound Amiblu pipes.

Diameter range (OD)272-3600 mm
Pressure (PN)up to 6 bar
Amiblu stainless steel sleeve illustration

Commonly used for jacking and relining. Fits centrifugally cast and filament wound Amiblu pipes.

Diameter range (OD)272-3600 mm
Pressure (PN)up to 6 bar
Amiblu stainless steel and rubber sleeve illustration

Commonly used for jacking and relining. Fits centrifugally cast and filament wound Amiblu pipes.

Diameter range (OD)272-2500 mm
Pressure (PN)up to 16 bar

Other joints and couplings

Field joints for pressure & gravity applications
Laminated field joints are available in uniaxial and biaxial designs. Amiblu provides the necessary instructions or skilled personnel for butt-wrap joining in pressure and non-pressure applications. Technologies developed by Amiblu provide faster and more cost-efficient installations.

 

Masonry couplings
The masonry coupling is used for connecting pipes to concrete shafts and walls. Masonry couplings are sanded for improved stability in concrete shafts. Masonry couplings can be delivered with pipe ring, and optionally with sealing tape. Lengths can be selected as required in consideration of the pipe joint data.

 

Mechanical couplings
Amiblu pipes can be joined using steel couplings. Examples of steel couplings are the tangential bolt couplings of Straub, Tee-Kay and Arpol, and the axial bolt couplings of Viking Johnson, Helden, and Klamflex.

 

Amiblu flanges
Amiblu manufactures and sells flanges in various designs and according to different standards and requirements. When connecting two GRP flanges, the standard bolt pattern to which flanges are manufactured is EN 1092. Other bolting dimension systems such as according to AWWA, ANSI, DIN, and JIS can be supplied.

Pressure couplings

Hobas filament wound coupling illustration

Used in pressure and non-pressure pipelines.

Diameter range (DN)200-3600 mm
Pressure (PN)< DN 1000: up to 32 bar

> DN 1000: max. 20 bar

Angular deflection*up to 3°
Flowtite pressure coupling illustration

Commonly used for penstocks, water supply, irrigation and pressure sewer applications.

Diameter range (DN)100-4000 mm
Pressure (PN)up to 32 bar
Angular deflection*up to 3°
Flowtite pressure coupling angled illustration

Flowtite coupling for increased angular deflections up to 3 degrees.

Diameter range (DN)300-2500 mm
Pressure (PN)up to 16 bar
Angular deflection*
Flowtite lock joint illustration

Biaxial joint used for applications where transfer of load between pipes is required.

Diameter range (DN)300-2000 mm
Pressure (PN)6-16 bar
Angular deflection*not applicable

Non-pressure couplings

Flowtite non-pressure coupling illustration

Commonly used for sewer and stormwater applications with Flowtite pipes.

Diameter range (DN)300-3000 mm
Pressure (PN)1 bar
Angular deflection*up to 3°
Amiblu non-pressure coupling illustration

Alternative coupling for sewer and stormwater applications with Hobas pipes.

Diameter range (DN)200-3000 mm
Pressure (PN)1 bar
Angular deflection*up to 3°

* The degree of angular deflection is dependent on the pipe diameter. Contact your local supplier for more information.

Flush joints

Amiblu GRP sleeve illustration

Commonly used for jacking and relining. Fits centrifugally cast and filament wound Amiblu pipes.

Diameter range (OD)272-3600 mm
Pressure (PN)up to 6 bar
Amiblu stainless steel sleeve illustration

Commonly used for jacking and relining. Fits centrifugally cast and filament wound Amiblu pipes.

Diameter range (OD)272-3600 mm
Pressure (PN)up to 6 bar
Amiblu stainless steel and rubber sleeve illustration

Commonly used for jacking and relining. Fits centrifugally cast and filament wound Amiblu pipes.

Diameter range (OD)272-2500 mm
Pressure (PN)up to 16 bar

Other joints and couplings

Field joints for pressure & gravity applications
Laminated field joints are available in uniaxial and biaxial designs. Amiblu provides the necessary instructions or skilled personnel for butt-wrap joining in pressure and non-pressure applications. Technologies developed by Amiblu provide faster and more cost-efficient installations.

 

Masonry couplings
The masonry coupling is used for connecting pipes to concrete shafts and walls. Masonry couplings are sanded for improved stability in concrete shafts. Masonry couplings can be delivered with pipe ring, and optionally with sealing tape. Lengths can be selected as required in consideration of the pipe joint data.

 

Mechanical couplings
Amiblu pipes can be joined using steel couplings. Examples of steel couplings are the tangential bolt couplings of Straub, Tee-Kay and Arpol, and the axial bolt couplings of Viking Johnson, Helden, and Klamflex.

 

Amiblu flanges
Amiblu manufactures and sells flanges in various designs and according to different standards and requirements. When connecting two GRP flanges, the standard bolt pattern to which flanges are manufactured is EN 1092. Other bolting dimension systems such as according to AWWA, ANSI, DIN, and JIS can be supplied.